BK PRECISION 1623A CALIBRATION and BK PRECISION 1623A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 1623A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   BK PRECISION 1623A   Description / Specification:    
BK PRECISION 1623A 60V 1.5A Single Output Digital Display DC Power Supply

The BK Precision 1623A 0 to 60V, 0 to 1.5A Digital Display DC Power Supply has both coarse and fine voltage and current control knobs and dual LED displays to continuously monitor both output current down to 10 mA and voltage down to 100 mV. Features; Continuously monitor voltage and current output on two digital meters. Connect two supplies in parallel to double the current output. Connect two supplies in series to double the voltage output. Operate continuously at full load without overheating. Fully overload protected. Coarse and fine voltage controls. Constant voltage or constant current operation. Specifications. Output Voltage: 0 to 60 V. Output Current: 0 to 1.5 A. Constant Voltage Operation Voltage Regulation Line (120VAC ±10%, -6%): <= 0.02% + 3 mV. Voltage Regulation Load (no load - full load): <= 0.02% + 3 mV. Recovery Time: <= 500 ms. Ripple & Noise: 0.5 mVrms (Typical). Temperature Coefficient: <= 300 ppm/°C. Constant Current Operation Adjustable Current Limit: 0-100%. Current Regulation Line (120VAC ±10%): <= 0.02% + 3 mA. Current Regulation Load: <= 0.02% + 3 mA. Current Ripple: <= 3 mA. Metering Type: Dual 3-digit LED. Voltmeter Range: 0-60V. Voltmeter Accuracy: ±0.2% +2 digits. Ammeter Range: 0-9.99 A. Ammeter Accuracy: ±0.2% +2 digits. Overload Protection Current, limiting, reverse polarity, overvoltage, short circuit.



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 1623A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 1623A CALIBRATION and/or BK PRECISION 1623A 60V 1.5A Single Output Digital Display DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: